[AGIPD][CORRECT] Attenuator correction to be tested at SPB

Karim Ahmed requested to merge feat/extra_correct_step into master

Description

This is a preparation for the attenuator to be tested at SPB.

Here is a last correction step to perform Attenuator Correction to counteract the effects of the attenuator physical map applied on the detector.

Marcin plans on doing a test this Wednesday to add a physical attenuator map on the detector to reduce the beam intensity applied on it's center to protect the detector and at the same time capture the data close to the corners which is the data of interest.

How Has This Been Tested?

  • TBD

Relevant Documents (optional)

Types of changes

  • New feature (non-breaking change which adds functionality)

Checklist:

Reviewers

@schmidtp @hammerd